Today o hagin has local and national testing approvals.
Fire rated roof vent intake.
Alternatively cover all existing vent openings with 1 8 inch or 1 16 inch wire mesh.
Smartvent also satisfies all ridge vent and exhaust vent requirements.
Ember and fire resistant vent u s.
As part of a ventsure balanced air ventilation system of intake and exhaust the ventsure inflow vent helps reduce heat and moisture buildup that can lead to ice damming and roof deterioration.
An air intake or exhaust vent for an external roof or wall of a building.
Of vent opening you have to also adjust the calculation for the degree to which the vent opening is obstructed by mesh screening and any other airflow obstructions such as under sized cuts into the roof deck.
The inflow vent is an ideal solution for roofs without soffits or used as a supplemental intake on roofs requiring additional ventilation.
Patent numbers 6 212 833 6 447 392 issued by the united states patent trademark office.
Accommodates roof pitches from 3 12 to 16 12.
The best ventilation solution for tile roof applications in areas where rain or snow may be a concern.
Class a fire rated.
An ember catching screen blocks dangerous embers during ember attacks long before the fire arrives.
When a wildfire nears and the vent reaches the critical temperature the intumescent coating on the matrix structure expands creating an insulating barrier from fire and embers.
In general you want 2x as much intake venting at the eaves as outlet at the ridge but keep in mind that if you use a mesh type ridge vent the ridge opening is obstructed by the mesh and the air flow will may be insufficient so you can t just measure the sq in.
Use manufacured and ca approved vents see below to retrofit existing attic soffit basement foundation and gable vents where possible.
As seen on this old house vulcan vents are designed to be fire and ember safe.
Made with an internal weather filter.
This is a photograph from a test conducted in a fire research laboratory.
Wind driven rain resistant to 110 mph.
Patent application 11 875 034 filed october 19 2007.
We have been using smartvent for years as a great solution for inadequate ventilation on our customer s homes.
Each vent has 16 sq.
Available with and without nails.
Vents are vulnerable to wildfires when embers and flames enter into the enclosed attic or crawl spaces and ignite combustible materials in those areas.
Louver openings are sized to minimize insect infiltration and windblown debris.
Is recognized for its industry leading efforts in research development and testing.
Common 1 4 screens are ineffective and should be replaced or retrofitted.
Smartvent is rated at 9 nfa ft.
In addition to all the design construction features and color choices of the o hagin standard line this patent pending attic vent features an interior stainless steel diffuser that breaks down wind driven rain and snow before it can enter the attic space.
It shows fire penetrating a frieze block vent with flames entering into what would be the attic.